We are no longer offering this product.

The below information is presented for informational purposes only. You may also find similar items in the category.
SHOP ALL PRODUCTS
V

Xantrex 100KW 3-Phase 480VAC Inverter

Xantrex 100KW 3-Phase 480VAC Inverter
Xantrex 100KW 3-Phase 480VAC Inverter
 
Item code Brand name Model number Volts Watts
XANGT100-480 Xantrex GT100480 480V 100000W

Interested in seeing if you qualify for discounted dealer pricing?
Contact Alt-E Direct today at 1-800-320-9514 for more information.


XantrexXantrex Grid Tie Commercial Inverters
Three-Phase
GT100-208, GT100-480, GT250-480

 

GT Series Grid Tie Solar Inverters - Three Phase - North America

Xantrex commercial grid tie inverter

The Xantrex GT100 and GT250 incorporate an advanced Maximum Power Point Tracking (MPPT) algorithm to maximize the energy harvested from a PV array. To reduce power losses during the conversion process, the inverter uses the latest switching devices and a high-efficiency transformer to achieve a weighted CEC efficiency of 96%.

To ensure reliability, the Xantrex GT100 and GT250 and their sub-components are tested using Highly Accelerated Life Testing (HALT). HALT combines thermal and vibration technologies to stress a product beyond its specifications. This enables Xantrex to develop products and test them to a much higher standard than other inverter manufacturers. High reliability of the Xantrex GT100 and GT250 reduces system downtime and results in higher energy production.

Xantrex GT Series Grid Tie Solar Inverters are based on a reliable platform that is used in grid-connected photovoltaic (PV) and wind turbine applications throughout North America and Europe. 

Specifications

General Specifications
  GT100-208 GT100-480 GT250-480
Maximum continuous output power 100 kW 100 kW 250 kW
Nominal output voltage 208 Vac 480 Vac 480 Vac (line to line, +10%-12%)
Nominal output frequency 60 Hz 60 Hz 60 Hz (+0.5 Hz / -3.0 Hz)
Nominal output current 278 A rms 120 A rms 301 A rms
Maximum output fault current 1100 A peak 1100 A peak 1400 A peak (duration of 0.008 sec)
Power factor > 0.99 > 0.99 > 0.99
DC input voltage range 300-600 Vdc 300-600 Vdc 300-600 Vdc
Peak power tracking voltage range 300-480 Vdc 300-480 Vdc 300-480 Vdc
Maximum input current 347 Adc 347 Adc 867 Adc
Maximum input short-circuit current 460 Adc 460 Adc 1214 Adc
Maximum backfeed current 0 Adc 0 Adc 0 Adc
Peak inverter efficiency 96.2% 96.70% 96.80%
CEC efficiency 95.0% 96.00% 96.00%
Night-time power consumption < 100 W < 100 W < 100 W
Maximum output over-current protection 400 A 200 A 400 A
Mechanical Specifications
Operating temperature range -5°F to 122°F (-15° to 50°C)
Enclosure rating NEMA 3R (outdoor rating)
Enclosure   E-coated and powder coated steel enclosure
Unit weight 3000 lb (1361 kg) 3000 lb (1361 kg) 4000 lb (1814 kg)
Inverter dimensions (H x W x D) 73.3 x 67.0 x 46.1" 73.3 x 67.0 x 46.1" 86.3 x 90.0 x 46.1" 
  1862 x 1702 x 1171 mm 1862 x 1702 x 1171 mm 2192 x 2286 x 1171 mm (Removable air intake reduces depth by 12” for fitting through doors)
Noise < 70 dBA
Altitude up to 6600’ (2012 m) without de-rating
Relative humidity  0 to 95% non-condensing
Features & Options
Cooling method Forced convection cooling/sealed design
AC/DC disconnect Standard and integrated within the inverter enclosure
Isolation transformer Standard and integrated within the inverter enclosure
User display Standard bright fluorescent green vacuum display
Ground-fault detection/interruption Standard and integrated within the inverter enclosure
Communications Optional RS485/Modbus and RS232 communications
Sub-array combiner Optional and integrated within the inverter enclosure, 100 A circuits, other sizes available 
Regulatory Approvals
Certified to UL 1741 (2005 Edition) and CSA 107.1-01
Tested to IEEE 1547
FCC Part 15 Class A

Partial List of Accessories

Part Number Description
1-151258-01 CB10H15-3R Combiner box, 10 circuit, NEMA 3R, Fuses not included
1-151260-01 CB12H20-3R Combiner box, 12 circuit, NEMA 3R, Touch Safe, Fuses not included

1-153482-01


Communication Assembly,Copper Connection (required for remote monitoring by customer or third party)
1-153509-01 GT100 100A Input Fusing (6 x 100A)
1-153510-01 GT100 150A Input Fusing (4 x 150A)
1-153511-01 GT100 200A Input Fusing (3 x 200A)
1-153512-01 GT250 100A Input Fusing (15 x 100A)
1-153513-01 GT250 150A Input Fusing (10 x 150A)
1-153514-01 GT250 200A Input Fusing (7 x 200A)

 

 

 

 

 

Xantrex


Click here for BBB Business Review ASE NESEA Member
Paypal Visa MasterCard Amex Discover
McAfee SECURE sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams