MidNite Solar MNE175XWP-SLAVE 175 Amp E-Panel for Schneider Electric XW+ Inverter
MidNite Solar MNE175XWP-SLAVE 175 Amp E-Panel for Schneider Electric XW+ Inverter
Couldn't load pickup availability
Note: The Inverter and charge controller are not included with the E-Panel.
This E-Panel is set up for a slave configuration. This is for a system in which you plan to have two or more XW+ inverters connected in parallel. A master configuration E-Panel is also necessary for this type of setup. If you plan to use only one XW+ inverer, that requires a single configuration E-Panel.
The MidNite Solar E-Panel simplifies the installation process for your Xantrex inverter system. It comes with all the properly sized over-current devices like circuit breakers and DC disconnects as required by the national electric code. All MidNite E-Panels are ETL listed to UL and CSA standards and can be used in residential and small commercial installations. The design of the E-Panel allows the inverter to mount directly above the E-Panel enclosure. This saves you wall space, time, and some money (no additional conduits or enclosures are necessary for connecting the inverter to the E-Panel). The panel comes factory pre-wired and all field wiring connection points are clearly labeled (solar, battery, generator, etc.). The XW E-Panel comes standard with a reversible door hinge and can be switched in the field. The XW+ E-Panels are only available in steel. If you are interested in shortening install time, saving money and being NEC code compliant, then you may want to consider a MidNite Solar E-Panel. If you have any questions about choosing the proper E-Panel, feel free to email us or call for more information.
The XW+ inverter mounts to the top of the E-Panel and the XW MPPT 60 amp charge controller mounts to either side. If you plan to use an Outback or MidNite Solar charge controller, those will require a mounting bracket. A right side bracket is included with the unit. If you need a left side mounting bracket, that is an additional $15.
Share

Once I got the plan set, it was easy to install... it was amazing how quick it went once everything was all set up. I knew what to expect, I knew what the inspector would be looking for... you guys were there to back me up, so it was the smartest option for me.
Dan F.

You guys are my guys when it comes to solar. When I got stuck, making a phone call or appointment was one of the huge keys to how well this worked. The confidence and encouragement... it validated that I could do it.
Mike O.

As a DIYer, it's all plug and play, so it's incredibly straightforward... you have certified engineers doing your designs, therefore they're gonna be safe electrically and structurally. That to me is a big peace of mind when I did this.
Tim G.